Geozondas manufactures subnanosecond, nanosecond and picosecond pulse generators, monocycle pulse genarators, UWB antennas, programmable delay lines, pulse splitters, sampling oscilloscopes, rotary positioners, non-linear pulse amplifiers-drivers, Sample and Hold samplers for UWB radar measurement systems.

Please select product group from list below for comparison of main characteristics of different available up-to-date models in these groups.

Nanosecond Picosecond Pulse Generators & Monocycle Pulse Genarators
Through wall radar system
Sampling oscilloscopes
UWB Antennas
Pulse Generator Mainframes
Rotary Positioners
Programable Digital Delay Line
Non-Linear Pulse Amplifier (PULSE FORMER)
Pulse Splitter - Non Linear Pulse Amplifier
Sample & Hold

Digital Sampling Oscilloscopes for Comparison
Digital Sampling Oscilloscopes for Comparison

ModelNumber Of Channels Bandwidth Sampling Rate Dynamic
Range
Time BaseNoise (RMS)
Typical
Jitter
Typical
SD-10820

8 0.2÷20 GHz1 MHz ±500 mV (0.002 ÷ 20) ns/div
(adjustable with step 0.002 ns/div)
1.8 mV
(after substruction
of 0 line)
8 ps (2 ps RMS)
(@ Fine Delay 0÷1 ns)
SD203TM-26(7M)

2 (0÷26) GHz7000 kHz ±1000 mV (0.002 ÷ 6) ns/div
@ Sampl.Rate 7 MHz
(0.002 ÷ 8.2) ns/div
@ Sampl.Rate 6 MHz
(0.002 ÷ 9.4) ns/div
@ Sampl.Rate 5 MHz
(adjustable with step 0.002 ns/div)
1.6 mV 8 ps (2 ps RMS)
(@ Fine Delay 0÷1 ns)
SD203TMS-18A

2 (0.1÷18) GHz1000 kHz ±1000 mV (0.002 ÷ 200) ns/div
(adjustable with step 0.002 ns/div)
1.2 mV 8 ps (2 ps RMS)
(@ Fine Delay 0÷1 ns)
SD203TMS-26A

2 (0.1÷26) GHz1000 kHz ±1000 mV (0.002 ÷ 200) ns/div
(adjustable with step 0.002 ns/div)
1.6 mV 8 ps (2 ps RMS)
(@ Fine Delay 0÷1 ns)
SD203TMS-40A

2 (0.1÷40) GHz1000 kHz ±1000 mV (0.002 ÷ 200) ns/div
(adjustable with step 0.002 ns/div)
2 mV 8 ps (2 ps RMS)
(@ Fine Delay 0÷1 ns)
Sampling Oscilloscopes for UWB Radar Kits
Sampling Oscilloscopes for UWB Radar Kits

ModelChannels Bandwidth Dynamic
Range
Noise RMSTime Window
(Electrical Length)
ResolutionPRF Operating
Modes
GZ10M

1 (0,1-10,6)GHz±500 mV1,2 mV100 ns/screen1,5 ps/point1,0 MHz; 500 kHz; 200 kHz; 100 kHz; 50 kHzInternal (TDR)
GZ10M2

2 (0,1-10,6)GHz±500 mV1,2 mV100 ns/screen1,5 ps/point1,0 MHz; 500 kHz; 200 kHz; 100 kHz; 50 kHzInternal (TDR)
GZ10

1 or 2 (0,1-10,6)GHz±500 mV1,3 mV100 ns/screen1,5 ps/point500 kHzExternal trigger
Real time scanning
(Life signals on screen)
GZ6E

1 or 2 (0,1–6) GHz ±500 mV0,85 mV100 ns/screen
(0,15–15)m
@ ε =1,0
12,5 ps/point (0,0037)m
@ ε =l,0
250 kHzReal time scanning
(Life signals on screen)